HELIO² 双轴跟踪支架
Every ray, turned into gain.
Single-column solar tracking racking carrying 8–24 modules, built for mountainous terrain, agrivoltaic fields and utility-scale plants; ±0.5° tracking accuracy and a typical 30–40% gain over fixed-tilt arrays (typical values).
HELIO² Solar Tracking Racking
Dual-axis smart tracking · ±0.5° full-sky accuracy
TG-24
Single-column dual-axis · 24-module class
- Azimuth ±180° rotation / tilt 0–70° swing
- ±0.5°
TG-8 V3
Single-column dual-axis · 8-module class
- Azimuth ±180° rotation / tilt 0–70° swing
SZGZ-X
Rectangular dual-axis · 8 / 10 / 12 module class
- Azimuth ±180° / tilt 0 – 85°
- ±0.5° (nominal)
Gain, computed.
30
%
Annual energy gain
Dual axes track the sun all day; typical value versus fixed-tilt plants, varying with latitude and irradiance.
80
%
O&M labour cost
Cloud-based remote monitoring and diagnostics keep site crews small and flag faults early.
60
%
Lifetime LCOE
Software and hardware are co-optimised from siting models to daily operation, lifting project IRR.
±0.5°
Tracking accuracy
Roughly 2–4× the common industry level; the gap widens most in early-morning and late-afternoon light.
25
years
Design life
Structure, drive and control are engineered for the full lifecycle, with automatic stow posture in extreme weather.
Wherever the sun goes, the array follows.
From mountains to islands, from farmland to business parks — one solar tracking racking covers the main terrains.




Three models, line by line.
Model
Model
TG-24
Single-slew + single-actuator solar tracking racking
TG-8 V3
Single-slew + single-actuator solar tracking racking
SZGZ-X
Dual-slew tracking PV station
Ordering model
TG-24
WZPV-SZTZ-24
TG-8 V3
WZPV-SZTZ-8
SZGZ-X
WZPV-SZGZ-8 / 10 / 12
Module count
TG-24
24 modules
- Crystalline silicon PV modules; dimensions and weight must match
TG-8 V3
8 modules
- 8 positions, 2 × 4 layout
- PV modules are not included in the racking supply
SZGZ-X
8 – 16 modules (configurable)
- Reference module: ZNSHINE N-type SMBB monocrystalline silicon, 650 W
- Module outline, mass, clamping zone and racking interface to be confirmed together
DC nominal capacity
TG-24
17.76 kWp
- 24 × 740 W modules
TG-8 V3
5.12–5.32 kWp
- 8 × 640–665 W modules (STC nameplate total)
SZGZ-X
5.2 – 10.4 kWp
- 8 × 650 W = 5.2 kWp
- 16 × 650 W = 10.4 kWp (mounting example)
Tracking performance
Tracking range
TG-24
Azimuth ±180° rotation / tilt 0–70° swing
Both axes are driven independently; azimuth and tilt operating ranges can be set separately
TG-8 V3
Azimuth ±180° rotation / tilt 0–70° swing
Both axes are driven independently; azimuth and tilt operating ranges can be set separately
SZGZ-X
Azimuth ±180° / tilt 0 – 85°
Actual software limits depend on the delivered version
Tracking accuracy
TG-24
±0.5°
TG-8 V3
—
SZGZ-X
±0.5° (nominal)
Tracking algorithm
TG-24
SmartTrack™ 3.0
Astronomical calculation combined with edge computing
Local irradiance and weather correction keeps tracking under overcast diffuse light
TG-8 V3
—
SZGZ-X
SmartTrack 3.0
Five coordinated layers: sensing, data, algorithm, decision, execution
System efficiency
TG-24
≥ 22.95%
TG-8 V3
—
SZGZ-X
—
MTBF
TG-24
≥ 100,000 hours
TG-8 V3
—
SZGZ-X
—
Drive architecture
Drive architecture
TG-24
Single-column dual-axis · 1 slew drive + 2 electric actuators
TG-8 V3
Single-column dual-axis · 1 azimuth slew + 1 rear actuator
SZGZ-X
Rectangular dual-axis · 2 DC gear motors
Mechanical architecture
TG-24
1 slew drive / 2 electric actuators / 8 mechanical dampers
Slew drive: 1 unit, azimuth drive and bearing clearly separated
Electric actuators: 2 units turning axial stroke into tilt motion
Mechanical dampers: 8 units, distributed connections with multi-position buffering
TG-8 V3
1 azimuth slew / 1 rear actuator / 2 mechanical dampers
Azimuth slew: SE7A-57MHD-24HRC-1202 Rev.C, 1 unit
Rear actuator: HB-DJ817W / Y817W-260328A1, 1 unit
Mechanical dampers: S30-535QQ-BE12-20260326, 2 units
SZGZ-X
One DC gear motor per axis, 2 in total
Auto-lock on power loss; lifetime maintenance-free lubrication
Part numbers listed in the BOM
Slew output torque
TG-24
Normal 14,688 N·m / max. 24,480 N·m
Assembly-level values, not motor shaft values
TG-8 V3
Normal 1,026 N·m / max. 1,596 N·m (up to 3 s)
Assembly-level values, not motor-shaft figures
SZGZ-X
Rated torque 120 N·m (motor component figure)
Not a system output, consumption or load-bearing figure
Overturning moment
TG-24
16,350 N·m
Selection must check output torque and combined loads together; no single parameter replaces the full load assessment
TG-8 V3
Tilting moment 7,000 N·m / holding moment 13,500 N·m
Axial / radial rated load 34 / 58 kN
SZGZ-X
—
Gear ratio / output speed
TG-24
102 : 1 / 0.016 r/min
TG-8 V3
57 : 1 / 0.02 rpm
SZGZ-X
736 : 1
Actuator stroke
TG-24
300 ± 3 mm
Minimum installation distance 800 ± 3 mm
TG-8 V3
300 ± 3 mm
Minimum installation centre distance 800 ± 3 mm
SZGZ-X
—
Actuator dynamic / static load
TG-24
Max. dynamic load 25 kN per unit / conditional static load 50 kN (half stroke)
TG-8 V3
Max. dynamic load 25 kN per unit / conditional static load 50 kN (half stroke)
SZGZ-X
—
Drive power supply
TG-24
24 V DC matched drive
Actuator max. current 5 A, duty cycle ≤ 10 %
TG-8 V3
24 V DC matched drive
Actuator max. current 5 A, duty cycle ≤ 10 %
SZGZ-X
24 V DC drive; control / auxiliary circuit 220 VAC / 24 VDC
Matched motor IP65 / −40 to +80 °C
Damper piston speed
TG-24
0.02 – 0.66 m/s
TG-8 V3
0.02 – 0.66 m/s
SZGZ-X
—
Reference damping force
TG-24
1.0 – 9.0 kN
0.02 m/s: approx. 1.0 kN
0.20 m/s: approx. 4.0 kN
0.50 m/s: approx. 7.5 kN
0.66 m/s: approx. 9.0 kN
TG-8 V3
1.0 – 9.0 kN
0.02 m/s: 1,000 N
0.20 m/s: 4,000 N
0.50 m/s: 7,500 N
0.66 m/s: 9,000 N
SZGZ-X
—
Structural protection
Wind resistance class
TG-24
Operating class 10 / protection class 12+
Once project-defined protection conditions are reached, normal tracking stops and protective action is executed
TG-8 V3
—
SZGZ-X
—
Enclosure protection
TG-24
Enhanced snow load / wide-temperature components / three-level lightning protection
Under snow conditions the tilt is adjusted per project strategy and snow is shed automatically
TG-8 V3
Slew drive IP66 / −40 to +80 °C
Actuator IP66 / C3 corrosion class / −20 to +60 °C
SZGZ-X
System IP54 / −25 to 60 °C / humidity 0–85 %
Matched motor IP65 (rated separately from system IP54)
Design life
TG-24
25 years
TG-8 V3
—
SZGZ-X
—
Dimensions
Array footprint (horizontal)
TG-24
approx. 9870 × 6940 mm
TG-8 V3
—
SZGZ-X
Reference outline 4.8 × 4.6 × 3.1 m
- Two further reference outlines: 4.7 × 4.6 × 3.4 m / 4.7 × 9.3 × 3.9 m
- The source drawing marks a 4800 mm span and a 3100 mm height
Ground to slew base
TG-24
4080 mm
- Not the overall machine height
TG-8 V3
—
SZGZ-X
Column height 2.1 m or 2.6 m
- Outline-to-module-count mapping per the mechanical drawing
Tilt reference (70°)
TG-24
Top 8530 mm / bottom edge 2010 mm
- Not equivalent to the full motion envelope or permitted operating angles
TG-8 V3
—
SZGZ-X
—
- A "—" means the item does not apply to that model, or must be issued separately against the approved project drawing and structural calculation report; ratings and dimensions are model-specific.
- DC nominal capacity is derived from the module count and module power in this table; it is not an instantaneous guaranteed output, nor does it equal annual energy yield.
- Class 12 is a design rating under the specified protective posture, project foundation and installation conditions, and does not mean normal operation in Class 12 winds; mechanical damping is dynamic cushioning, not static load bearing, and does not add up to a wind-resistance rating.
- Dimensions are in mm; specifications on this page are subject to the final order and project documents.