HELIO² Solar Tracking Racking

HELIO² 双轴跟踪支架

Every ray, turned into gain.

Single-column solar tracking racking carrying 8–24 modules, built for mountainous terrain, agrivoltaic fields and utility-scale plants; ±0.5° tracking accuracy and a typical 30–40% gain over fixed-tilt arrays (typical values).

Application scenes

Wherever the sun goes, the array follows.

From mountains to islands, from farmland to business parks — one solar tracking racking covers the main terrains.

Mountainous terrain · Follows the slope
Mountainous terrain · Follows the slope Rugged terrain, still squared to the sun. Slope and orientation adapt automatically so every module faces the light.
Off-grid island · Diesel to solar
Off-grid island · Diesel to solar Off the grid, still a steady daytime supply. Working with storage, it widens the off-grid power window.
Agrivoltaics · Two yields per acre
Agrivoltaics · Two yields per acre Power above, farming below. Pile foundations take little ground, so generation and cultivation coexist.
Business park · Install and go
Business park · Install and go Install it on the green and go. The column-mounted design blends naturally with the surroundings.
Technical specifications

Three models, line by line.

Model

Model
TG-24 Single-slew + single-actuator solar tracking racking
TG-8 V3 Single-slew + single-actuator solar tracking racking
SZGZ-X Dual-slew tracking PV station
Ordering model
TG-24 WZPV-SZTZ-24
TG-8 V3 WZPV-SZTZ-8
SZGZ-X WZPV-SZGZ-8 / 10 / 12
Module count
TG-24 24 modules
  • Crystalline silicon PV modules; dimensions and weight must match
TG-8 V3 8 modules
  • 8 positions, 2 × 4 layout
  • PV modules are not included in the racking supply
SZGZ-X 8 – 16 modules (configurable)
  • Reference module: ZNSHINE N-type SMBB monocrystalline silicon, 650 W
  • Module outline, mass, clamping zone and racking interface to be confirmed together
DC nominal capacity
TG-24 17.76 kWp
  • 24 × 740 W modules
TG-8 V3 5.12–5.32 kWp
  • 8 × 640–665 W modules (STC nameplate total)
SZGZ-X 5.2 – 10.4 kWp
  • 8 × 650 W = 5.2 kWp
  • 16 × 650 W = 10.4 kWp (mounting example)

Tracking performance

Tracking range
TG-24 Azimuth ±180° rotation / tilt 0–70° swing Both axes are driven independently; azimuth and tilt operating ranges can be set separately
TG-8 V3 Azimuth ±180° rotation / tilt 0–70° swing Both axes are driven independently; azimuth and tilt operating ranges can be set separately
SZGZ-X Azimuth ±180° / tilt 0 – 85° Actual software limits depend on the delivered version
Tracking accuracy
TG-24 ±0.5°
TG-8 V3 —
SZGZ-X ±0.5° (nominal)
Tracking algorithm
TG-24 SmartTrack™ 3.0 Astronomical calculation combined with edge computing Local irradiance and weather correction keeps tracking under overcast diffuse light
TG-8 V3 —
SZGZ-X SmartTrack 3.0 Five coordinated layers: sensing, data, algorithm, decision, execution
System efficiency
TG-24 ≥ 22.95%
TG-8 V3 —
SZGZ-X —
MTBF
TG-24 ≥ 100,000 hours
TG-8 V3 —
SZGZ-X —

Drive architecture

Drive architecture
TG-24 Single-column dual-axis · 1 slew drive + 2 electric actuators
TG-8 V3 Single-column dual-axis · 1 azimuth slew + 1 rear actuator
SZGZ-X Rectangular dual-axis · 2 DC gear motors
Mechanical architecture
TG-24 1 slew drive / 2 electric actuators / 8 mechanical dampers Slew drive: 1 unit, azimuth drive and bearing clearly separated Electric actuators: 2 units turning axial stroke into tilt motion Mechanical dampers: 8 units, distributed connections with multi-position buffering
TG-8 V3 1 azimuth slew / 1 rear actuator / 2 mechanical dampers Azimuth slew: SE7A-57MHD-24HRC-1202 Rev.C, 1 unit Rear actuator: HB-DJ817W / Y817W-260328A1, 1 unit Mechanical dampers: S30-535QQ-BE12-20260326, 2 units
SZGZ-X One DC gear motor per axis, 2 in total Auto-lock on power loss; lifetime maintenance-free lubrication Part numbers listed in the BOM
Slew output torque
TG-24 Normal 14,688 N·m / max. 24,480 N·m Assembly-level values, not motor shaft values
TG-8 V3 Normal 1,026 N·m / max. 1,596 N·m (up to 3 s) Assembly-level values, not motor-shaft figures
SZGZ-X Rated torque 120 N·m (motor component figure) Not a system output, consumption or load-bearing figure
Overturning moment
TG-24 16,350 N·m Selection must check output torque and combined loads together; no single parameter replaces the full load assessment
TG-8 V3 Tilting moment 7,000 N·m / holding moment 13,500 N·m Axial / radial rated load 34 / 58 kN
SZGZ-X —
Gear ratio / output speed
TG-24 102 : 1 / 0.016 r/min
TG-8 V3 57 : 1 / 0.02 rpm
SZGZ-X 736 : 1
Actuator stroke
TG-24 300 ± 3 mm Minimum installation distance 800 ± 3 mm
TG-8 V3 300 ± 3 mm Minimum installation centre distance 800 ± 3 mm
SZGZ-X —
Actuator dynamic / static load
TG-24 Max. dynamic load 25 kN per unit / conditional static load 50 kN (half stroke)
TG-8 V3 Max. dynamic load 25 kN per unit / conditional static load 50 kN (half stroke)
SZGZ-X —
Drive power supply
TG-24 24 V DC matched drive Actuator max. current 5 A, duty cycle ≤ 10 %
TG-8 V3 24 V DC matched drive Actuator max. current 5 A, duty cycle ≤ 10 %
SZGZ-X 24 V DC drive; control / auxiliary circuit 220 VAC / 24 VDC Matched motor IP65 / −40 to +80 °C
Damper piston speed
TG-24 0.02 – 0.66 m/s
TG-8 V3 0.02 – 0.66 m/s
SZGZ-X —
Reference damping force
TG-24 1.0 – 9.0 kN 0.02 m/s: approx. 1.0 kN 0.20 m/s: approx. 4.0 kN 0.50 m/s: approx. 7.5 kN 0.66 m/s: approx. 9.0 kN
TG-8 V3 1.0 – 9.0 kN 0.02 m/s: 1,000 N 0.20 m/s: 4,000 N 0.50 m/s: 7,500 N 0.66 m/s: 9,000 N
SZGZ-X —

Structural protection

Wind resistance class
TG-24 Operating class 10 / protection class 12+ Once project-defined protection conditions are reached, normal tracking stops and protective action is executed
TG-8 V3 —
SZGZ-X —
Enclosure protection
TG-24 Enhanced snow load / wide-temperature components / three-level lightning protection Under snow conditions the tilt is adjusted per project strategy and snow is shed automatically
TG-8 V3 Slew drive IP66 / −40 to +80 °C Actuator IP66 / C3 corrosion class / −20 to +60 °C
SZGZ-X System IP54 / −25 to 60 °C / humidity 0–85 % Matched motor IP65 (rated separately from system IP54)
Design life
TG-24 25 years
TG-8 V3 —
SZGZ-X —

Dimensions

Array footprint (horizontal)
TG-24 approx. 9870 × 6940 mm
TG-8 V3 —
SZGZ-X Reference outline 4.8 × 4.6 × 3.1 m
  • Two further reference outlines: 4.7 × 4.6 × 3.4 m / 4.7 × 9.3 × 3.9 m
  • The source drawing marks a 4800 mm span and a 3100 mm height
Ground to slew base
TG-24 4080 mm
  • Not the overall machine height
TG-8 V3 —
SZGZ-X Column height 2.1 m or 2.6 m
  • Outline-to-module-count mapping per the mechanical drawing
Tilt reference (70°)
TG-24 Top 8530 mm / bottom edge 2010 mm
  • Not equivalent to the full motion envelope or permitted operating angles
TG-8 V3 —
SZGZ-X —
  1. A "—" means the item does not apply to that model, or must be issued separately against the approved project drawing and structural calculation report; ratings and dimensions are model-specific.
  2. DC nominal capacity is derived from the module count and module power in this table; it is not an instantaneous guaranteed output, nor does it equal annual energy yield.
  3. Class 12 is a design rating under the specified protective posture, project foundation and installation conditions, and does not mean normal operation in Class 12 winds; mechanical damping is dynamic cushioning, not static load bearing, and does not add up to a wind-resistance rating.
  4. Dimensions are in mm; specifications on this page are subject to the final order and project documents.