SZGZ-X Solar Tracking Racking
SZGZ-X Solar Tracking Racking

SZGZ-X Dual-Axis Solar Tracker · Interactive 3D Demo

Eight scenes explain one eight-module dual-axis tracking power station: 8 × 620 W PV modules (2.3 × 1.1 m) with a nominal capacity of 4.96 kWp, dual-motor azimuth and tilt drive, 176 original CAD parts in 9 assembly groups, an SDE7A slew drive, eight native purlins and horizontal / tilt limit interlocks, closing on an exploded view of the whole station.

01 Overview

SZGZ-X

Our in-house solar tracking racking is different from fixed racks and single-axis trackers. It adjusts azimuth and tilt at the same time, keeping the modules at the best angle to the sun all day. Load-bearing structure, dual-axis drive, position feedback, control strategy, safety protection and cloud O&M make up six parts that work together as one complete solar tracking system.

PV modules carried
8-24pcs
Energy yield gain
30%↑
O&M cost reduction
80%↓
  • Module array8 × 620 W · 4.96 kWp
  • Column & baseslew plane at 2.60 m
  • Slew driveSDE7A · dual motor

02 Dual-Axis Tracking

Azimuth Slew + Tilt Motion

Powered by the SmartTrack™ 3.0 tracking algorithm: astronomical calculation and edge computing work together to stay locked on the sun's path; local irradiance and weather data correct the aim in real time, and tracking continues even under overcast diffuse light, with no grid power needed. Average annual yield is up 30%, and the winter peak gain can exceed 50%.

Tracking accuracy
±0.5°
Azimuth slew
±180°
Tilt travel
0–85°

03 Slew Drive Assembly

Slew Drive Assembly

The slew mechanism ties drive, reduction and bearing support together on the azimuth axis, turning the upper array horizontally to follow the sun's azimuth angle.

Slew drive
SDE7Adual motor
Drive assemblies
2motor barrels
Slew plane height
2.60m
  • Slew driveSDE7A · drive · reduction · bearing

04 Tilt Output

Tilt Output

The tilt motor turns the array about its native horizontal axis through the output plate and the round-shaft frame; eight native purlins and four angle beams carry the module load back to the tilt axis, with the travel range held by the tilt limit.

Tilt drive
SDE7Aoutput end
Tilt demo range
0–65°
Native purlins
8pcs
  • Tilt outputSDE7A · upper rotating end

05 Limits & Interlocks

Limits & Interlocks

One horizontal and one tilt limit bracket with two trigger paddles each, plus five M8 limit switches: the array stops when it reaches a travel boundary, and the azimuth and tilt ranges are held by the mechanism itself.

Horizontal limit
1set
Tilt limit
1set
Limit switches
5pcs · M8
  • Limits & interlockshorizontal / tilt limits · 5 M8 switches

06 Extreme Conditions

Extreme Weather Protection

Cloud early warningAuthoritative weather data looks 72 hours ahead at severe conditions so protection can be staged in advance.

Edge fast responseOn-board sensors monitor at millisecond resolution and automatically trigger high-wind and heavy-snow protection modes.

Hardened hardwareLevel-12 wind rating, reinforced snow load, wide-temperature components and three-stage lightning protection.

07 Global Smart Cloud Platform

Global Smart Cloud Platform

See the whole fleet on the desktop dashboard, check it anywhere from the App, with monitoring and control in one place. Equipment, generation, alarms and control cover the full plant O&M workflow and cut blind site inspections.

08 Exploded View

Structure, exploded

Nine factory groups stack up above the load-bearing column: the column-cap mount with its level stops, the dual-axis drive with its limit sensors, the tilt output coupling, the round-tube frame with its M8 locks, the four corner beams, the eight purlins, then the eight modules. The control box lifts off to one side. Every group ships pre-assembled — on site the station bolts together around the column.

Major assemblies
9groups
Original CAD parts
176pcs
Fasteners & joints
121pcs
  • Load-bearing columnfixed to the cap plate
  • Dual-axis driveSDE7A · azimuth + tilt
  • Module array8 × 620 W · 4.96 kWp
  • Tilt outputSDE7A · upper rotating end
Global Smart Cloud Platform · SZGZ-X 5G

Linked trackerAuto-linked

Sun azimuth
--°
Sun elevation
--°
Tracker azimuth
--°
Tracker elevation
--°

Today's PV power--

0006121824

Loading model 0%

Engineering, Made Visible

Advantage, hidden in every connection.

From array capacity down to every joint — each figure traces back to real structure and ledger records.

SZGZ-X rectangular eight-module array, front view
5.2 – 10.4 kWp

Rectangular array, module count to order.

8–16 module positions (8 / 10 / 12 tiers) take 650 W modules: 8 × 650 W = 5.2 kWp, 16 × 650 W = 10.4 kWp.

SZGZ-X dual rotation head on the rectangular frame, close-up
2 independent axes

Two rotations on one rectangular frame.

Azimuth and tilt each rotate independently on the frame — both mechanisms trace back to the original assembly.

SZGZ-X DC gear motor and control box close-up
736 : 1 / 120 N·m

Dual DC motors, 736 : 1 reduction.

Two DC gear motors drive through a 736 : 1 reduction; the 120 N·m rating is a motor-component figure, not a machine-output value.

SZGZ-X compact rectangular tracker, three-quarter view
4.8 × 4.6 × 3.1 m

Compact envelope, two post heights.

Reference envelope 4.8 × 4.6 × 3.1 m on 2.1 m or 2.6 m posts — sized for scattered terrain and agrivoltaic layouts.

SZGZ-X column and control box side view
IP54 / IP65 / −25 to 60 ℃

Sealed for weather, wide temperature band.

System IP54 with IP65 motors, −25 to 60 ℃ at 0–85 % humidity — protection figures taken straight from the spec sheet.

SZGZ-X frame connection node: beam and purlin joints
as drawn

How it bolts together is on the drawing.

Pins and bolts at the beam-to-purlin joints each carry a part number and an installation position on the assembly drawing — crews build to it, inspection checks against it.

Application Scenes

Any terrain, any climate.

Pile-mounted and self-adapting to the ground, it chases the light on any terrain: mountains, islands, farmland or business parks.

Dual-axis tracker at a mountain power plant
Mountain plantRugged terrain, still squared to the sun. Slope and orientation adapt automatically so every module faces the light.
SZGZ-XView specs ›
Dual-axis tracker in an off-grid island scene
Off-grid islandOff the grid, still a steady daytime supply. Working with storage, it widens the off-grid power window.
SZGZ-XView specs ›
Dual-axis tracker in an agrivoltaic scene
AgrivoltaicsPower above, farming below. Pile foundations take little ground, so generation and cultivation coexist.
SZGZ-XView specs ›
Dual-axis tracker in a business park
Business parkInstall it on the green and go. The column-mounted design blends naturally with the surroundings.
SZGZ-XView specs ›
Technical specifications

SZGZ-X technical specifications

SZGZ-X belongs to HELIO² 双轴跟踪支架; other models in the series can be compared on the series overview page.

Model

Model
SZGZ-X Dual-slew tracking PV station
Ordering model
SZGZ-X WZPV-SZGZ-8 / 10 / 12
Module count
SZGZ-X 8 – 16 modules (configurable)
  • Reference module: ZNSHINE N-type SMBB monocrystalline silicon, 650 W
  • Module outline, mass, clamping zone and racking interface to be confirmed together
DC nominal capacity
SZGZ-X 5.2 – 10.4 kWp
  • 8 × 650 W = 5.2 kWp
  • 16 × 650 W = 10.4 kWp (mounting example)

Tracking performance

Tracking range
SZGZ-X Azimuth ±180° / tilt 0 – 85° Actual software limits depend on the delivered version
Tracking accuracy
SZGZ-X ±0.5° (nominal)
Tracking algorithm
SZGZ-X SmartTrack 3.0 Five coordinated layers: sensing, data, algorithm, decision, execution

Drive architecture

Drive architecture
SZGZ-X Rectangular dual-axis · 2 DC gear motors
Mechanical architecture
SZGZ-X One DC gear motor per axis, 2 in total Auto-lock on power loss; lifetime maintenance-free lubrication Part numbers listed in the BOM
Slew output torque
SZGZ-X Rated torque 120 N·m (motor component figure) Not a system output, consumption or load-bearing figure
Gear ratio / output speed
SZGZ-X 736 : 1
Drive power supply
SZGZ-X 24 V DC drive; control / auxiliary circuit 220 VAC / 24 VDC Matched motor IP65 / −40 to +80 °C

Structural protection

Enclosure protection
SZGZ-X System IP54 / −25 to 60 °C / humidity 0–85 % Matched motor IP65 (rated separately from system IP54)

Dimensions

Array footprint (horizontal)
SZGZ-X Reference outline 4.8 × 4.6 × 3.1 m
  • Two further reference outlines: 4.7 × 4.6 × 3.4 m / 4.7 × 9.3 × 3.9 m
  • The source drawing marks a 4800 mm span and a 3100 mm height
Ground to slew base
SZGZ-X Column height 2.1 m or 2.6 m
  • Outline-to-module-count mapping per the mechanical drawing
  1. A "—" means the item does not apply to that model, or must be issued separately against the approved project drawing and structural calculation report; ratings and dimensions are model-specific.
  2. DC nominal capacity is derived from the module count and module power in this table; it is not an instantaneous guaranteed output, nor does it equal annual energy yield.
  3. Class 12 is a design rating under the specified protective posture, project foundation and installation conditions, and does not mean normal operation in Class 12 winds; mechanical damping is dynamic cushioning, not static load bearing, and does not add up to a wind-resistance rating.
  4. Dimensions are in mm; specifications on this page are subject to the final order and project documents.