Sentinal C&I ESS
Commercial & industrial storage,
integrated in one cabinet.
A 100–261 kWh liquid-cooled C&I storage series, from integrated PV-and-storage units to two-hour-class liquid-cooled cabinets, for projects with repeatable peaks and measurable solar shifting.
PV-storage integrated & liquid-cooled ESS
Hard numbers,
returns you can count.
8000
cycles
Cycle life @90% DOD
314 Ah large-format LFP cells. At one cycle a day, that is over 20 years.
98.5
%
Max discharge efficiency
Sentinal 261 reaches 98.5% max discharge efficiency, system efficiency ≥94%, so less energy is lost.
10
ms
Grid / off-grid switching
Sentinal 100 switches between grid-tied and off-grid in <10 ms, keeping critical loads running.
3
models
Capacity options
100 / 233 / 261 kWh, enough for peak-shaving and backup needs from parks to mid-size industry.
261
kWh
Max capacity per cabinet
The 125 kW / 261 kWh liquid-cooled flagship, with two-hour shifting and more controllable peak and demand savings.
At home in every kind of industrial site.
From urban parks to rural microgrids, Sentinal covers the main commercial and industrial storage scenarios with one product line.




Compare line by line, choose by need.
Core specifications
Form factor
Sentinal 100
All-in-one PV + storage cabinet (PCS, battery and MPPT integrated)
Sentinal 233
Liquid-cooled all-in-one storage cabinet (storage only, with PCS)
Sentinal 261
Liquid-cooled all-in-one storage cabinet
Rated power / capacity
Sentinal 100
50 kW / 100 kWh (96.46 kWh nominal battery energy)
Sentinal 233
105 kW / 233 kWh
Sentinal 261
125 kW / 261 kWh
Max PCS power
Sentinal 100
Sentinal 233
Sentinal 261
137 kW
Depth of discharge
Sentinal 100
Sentinal 233
DoD 98%
Sentinal 261
Cell chemistry
Sentinal 100
LFP 3.2 V · 314 Ah
Sentinal 233
LFP · 314 Ah large cells (common to the series)
Sentinal 261
LFP 3.2 V · 314 Ah (cell 71173204-314Ah)
Topology
Sentinal 100
96S1P (96 cells in series)
Sentinal 233
Sentinal 261
1P52S · 52.2 kWh per module
Nominal battery voltage
Sentinal 100
307.2 V (operating range 249.6 – 350.4 V)
Sentinal 233
Sentinal 261
Cluster voltage / cells
Sentinal 100
Sentinal 233
Sentinal 261
832 V nominal · 260 cells in series
Electrical performance
Max efficiency
Sentinal 100
98.2% (max) / 97.1% (European efficiency)
Sentinal 233
—
Sentinal 261
98.5%; operating efficiency ≥94%
Rated grid voltage
Sentinal 100
3L/N/PE · 380 V / 400 V, 50 Hz / 60 Hz
Sentinal 233
Sentinal 261
3L/N/PE · 380 V / 400 V
MPPT
Sentinal 100
4 MPPT · 180–900 V · 1000 V max (direct PV input)
Sentinal 233
Sentinal 261
Grid / off-grid transfer
Sentinal 100
<10 ms; EPS 75 kW / 10 s
Sentinal 233
— (storage-only cabinet; determined by the PCS)
Sentinal 261
Off-grid capability
Sentinal 100
Parallel up to 10 units (approx. 500 kW / 960 kWh)
Sentinal 233
Off-grid expansion cabinet
Sentinal 261
PV input
Sentinal 100
Sentinal 233
— (storage only; PV connected via PCS)
Sentinal 261
Generator support
Sentinal 100
50 kW diesel generator input
Sentinal 233
Sentinal 261
Communication
Sentinal 100
CAN / RS485 · COM port
Sentinal 233
RS485 / CAN
Sentinal 261
4G remote · CAN / RS485 on site
Monitoring
Sentinal 100
Sentinal 233
Sentinal 261
EMS / SCADA platform integration
Structure & protection
Cooling
Sentinal 100
Cabinet air conditioning (air-cooled)
Sentinal 233
Liquid cooling
Sentinal 261
Liquid cooling + dehumidification
Ingress protection
Sentinal 100
IP55 (complete cabinet)
Sentinal 233
IP54 (cabinet)
Sentinal 261
IP54 (cabinet) · IP65 (module)
Fire suppression
Sentinal 100
Sentinal 233
PACK-level + cluster-level (Novec 1230 / aerosol)
Sentinal 261
Corrosion protection
Sentinal 100
Sentinal 233
C5-M corrosion protection (entire series)
Sentinal 261
Operating temperature
Sentinal 100
−20 ~ 60 °C (derating above 45 °C)
Sentinal 233
−20 ~ 50 °C
Sentinal 261
−20 ~ 50 °C
Dimensions (W×D×H)
Sentinal 100
1125 × 1100 × 2150 mm
Sentinal 233
Sentinal 261
970 × 1400 × 2270 mm
Weight
Sentinal 100
Sentinal 233
Sentinal 261
Approx. 2350 ± 20 kg (fully equipped)
Scalability
Cycle life
Sentinal 100
≥8000 cycles @90% DOD
Sentinal 233
≥8000 cycles @90% DOD
Sentinal 261
≥8000 cycles @90% DOD
Multi-cabinet parallel
Sentinal 100
Sentinal 233
Cabinet-by-cabinet expansion; multi-cabinet parallel supported
Sentinal 261
Compliance & certification
IEC series
Sentinal 100
IEC 62109-1 · IEC 62109-2 · EN 61000
Sentinal 233
Sentinal 261
IEC 62619 · IEC 63056
Battery / safety
Sentinal 100
Sentinal 233
IEC 62619 / 63056
Sentinal 261
Transport
Sentinal 100
UN38.3
Sentinal 233
UN38.3
Sentinal 261
UN38.3
Grid connection / local
Sentinal 100
CEI 0-21 (Italy) · NRS 097-2-1:2017 (South Africa) · VDE-AR-N 4105:2018 (Germany) · COC 3310-2014 (China)
Sentinal 233
Per the regulations of the project location
Sentinal 261
CEI 0-21 (Italy) · NRS 097 (South Africa) · VDE-AR-N 4105 (Germany) · CQC 3310 (China)