Sentinal 100
All-in-one C&I PV + storage cabinet

A 50 kW / 100 kWh-class integrated platform for farms, processing sites, workshops and rural businesses seeking greater solar self-use, selected peak control and defined short-duration continuity.

Product features

What one cabinet can do

cell chemistry

LFP 3.2 V · 314 Ah

307.2V battery voltage

8000 cycles, 90% DOD

10units off-grid parallel

ingress protection

IP55 (complete cabinet)

communication ports

CAN / RS485 · COM port

Project fit

Start from the load curve and the tariff structure

Sentinal 100 is an all-in-one 50 kW / 100 kWh (96.46 kWh nominal battery energy) PV + storage cabinet. Selection comes down to the actual load curve, local tariffs (peak / valley and demand charges), grid-connection conditions and site environment, not the kWh rating alone.

Typical scenarios

Fully integrated, with PV coming straight in

  • Peak / valley arbitrageCharge in the valley and discharge at peak to shift demand and energy charges; it suits C&I tariffs with a wide spread
  • PV + storage4 MPPT, 180–900 V direct PV input; surplus PV is stored for night use
  • Backup / UPS<10 ms grid / off-grid transfer keeps critical loads running
  • Diesel + storage microgridAccepts a 50 kW diesel generator for continuous supply on weak or off-grid sites
  • Transformer deferralDispatch within the transformer capacity limit and defer costly upgrades
Request a tailored plan
Core data
0kWRated power
0kWhNominal energy
0%Max efficiency
0PV inputsMPPT inputs

LFP 314 Ah · 96S1P · IP55 air-conditioned

Specifications

Sentinal 100 detailed specifications

Core specifications

Model
OS-50KW-100KWh (Sentinal 100)
Form factor
All-in-one PV + storage cabinet (PCS, battery and MPPT integrated)
Rated power / capacity
50 kW / 100 kWh (96.46 kWh nominal battery energy)
Cell chemistry
LFP 3.2 V · 314 Ah
Topology
96S1P (96 cells in series)
Nominal battery voltage
307.2 V (operating range 249.6 – 350.4 V)

Electrical performance

Max efficiency
98.2% (max) / 97.1% (European efficiency)
Rated grid voltage
3L/N/PE · 380 V / 400 V, 50 Hz / 60 Hz
MPPT
4 MPPT · 180–900 V · 1000 V max (direct PV input)
Grid / off-grid transfer
<10 ms; EPS 75 kW / 10 s
Off-grid capability
Parallel up to 10 units (approx. 500 kW / 960 kWh)
Generator support
50 kW diesel generator input
Communication
CAN / RS485 · COM port

Structure & protection

Cooling
Cabinet air conditioning (air-cooled)
Ingress protection
IP55 (complete cabinet)
Operating temperature
−20 ~ 60 °C (derating above 45 °C)
Dimensions (W×D×H)
1125 × 1100 × 2150 mm

Scalability

Cycle life
≥8000 cycles @90% DOD

Compliance & certification

IEC series
IEC 62109-1 · IEC 62109-2 · EN 61000
Transport
UN38.3
Grid connection / local
CEI 0-21 (Italy) · NRS 097-2-1:2017 (South Africa) · VDE-AR-N 4105:2018 (Germany) · COC 3310-2014 (China)